Modular Piping – Data Centers

Clean, fast installs with prefabricated pipe racks, pump & heat-exchanger skids, and liquid-cooling modules (CDU/D2C/RDHx). Engineered for uptime and repeatability.

N+1 / 2N ArchitecturesOff-Site PrefabBIM / 3D CoordinationQA/QC & FAT
Request a Modular Quote

Where Modular Saves Time

Engineered solutions that reduce installation time, minimize field work, and ensure consistent quality across your data center infrastructure.

🔄

Hydronic Loops (CHW/CDW)

Header racks, valve groups, pump skids with VFDs, and HX interfaces sized for your load and redundancy requirements.

💧

Liquid Cooling

CDU platforms, D2C/RDHx manifolds, filtration, quick-connects, and leak detection with integrated BMS gateways.

🏗️

Pipe Racks & Risers

Grooved or welded assemblies with insulation jackets, supports, guides, and level isolation for seamless integration.

Modular Building Blocks

Pre-engineered, factory-tested components that integrate seamlessly to create complete piping systems for data center applications.

⚙️

Pump Skids

  • N+1 pumps w/ VFDs
  • Isolation & check valves
  • DP sensors & gauges
🔥

HX Skids

  • Plate & frame HX
  • 3‑way control valves
  • Glycol interface
🔍

Filtration Panels

  • Side‑stream filters
  • Magnetic separators
  • Cleanliness targets
💻

CDU Modules

  • Dual pumps & strainers
  • Fill/vent & air removal
  • Leak detection
🔧

Valve Groups

  • Isolation & bypass
  • Balancing valves
  • PT ports
🏗️

Header Racks

  • Grooved or welded
  • Insulation jackets
  • Supports & guides
📈

Riser Modules

  • Level isolation
  • Drains/vents
  • Seismic supports
📊

Control Panels

  • BMS gateways
  • Local HMI
  • Alarm systems

How We Deliver (Fast)

Streamlined process from design to commissioning, minimizing site disruption and maximizing installation efficiency.

  1. Design Assist & BIM

    3D coordination, hanger points, spool maps, and submittals aligned to your standards.

  2. Off‑Site Fabrication

    Shop welding/grooving, labeling, pressure tests with QA/QC traveler.

  3. Logistics & Kitting

    Just‑in‑time deliveries by zone; rack‑level kitting for rapid install.

  4. Installation

    Rigging plans, seismic bracing, torque/breakaway checks, insulation & jackets.

  5. Testing & Flush

    Hydrostatic tests, high‑velocity flush, chemical clean, glycol fill & balance.

  6. Commissioning

    Point‑to‑point, BMS integration, trending, O&M handover, and training.

Frequently Asked Questions

Common questions about our modular piping solutions and implementation process.

Can you match our corporate piping standards?

Yes—send your spec (materials, joints, labeling, insulation, QA/QC) and we'll map our modules to it.

How do you handle schedule risk?

We front‑load BIM coordination and fabricate off‑site in parallel with site readiness; deliveries arrive kitted by area to compress on‑site hours.

Can you provide liquid‑cooling (CDU/D2C/RDHx) modules?

Yes—CDU platforms, manifolds, quick‑connects, leak detection, and BMS gateways with FAT prior to shipment.

Let's Modularize Your Next Build

Send us your basis of design and site constraints. We'll return a layout, bill of modules, and schedule.